uScopeHXII

uScopeHXII ModelsuScopeHXII-10
Product Information
uScopeHXII-20
Product Information
uScopeHXII-40
Product Information
Objective110X 0.30NA
Plan APO
20X 0.65NA
Plan APO
40X 0.80NA
Plan APO
Camera2MP CMOS, High Speed2MP CMOS, High Speed2MP CMOS, High Speed
Camera Modes2
SD: 960×540
HD: 1920×1080
SD: 960×540
HD: 1920×1080
SD: 960×540
HD: 1920×1080
Pixel Mapping
SD: 1.00µm/pixel
HD: 0.50µm/pixel
SD: 0.50µm/pixel
HD: 0.25µm/pixel
SD: 0.25µm/pixel
HD: 0.125µm/pixel
Image Resolution
SD: 25,000 DPI
HD: 50,000 DPI
SD: 50,000 DPI
HD: 100,000 DPI
SD: 100,000 DPI
HD: 200,000 DPI
Field of View0.96mm × 0.54mm0.48mm × 0.27mm0.24mm × 0.13mm
Slide TrayPermanent, Non-RemovablePermanent, Non-RemovablePermanent, Non-Removable
Slide CapacitySingle SlideSingle SlideSingle Slide
Scan Mode
Normal (AutoFocus)
Z-Stacking3
EDF4 (Ext. Depth-of-Field)
Normal (AutoFocus)
Z-Stacking3
EDF4 (Ext. Depth-of-Field)
Normal (AutoFocus)
Z-Stacking3
EDF4 (Ext. Depth-of-Field)
Focus Method5
Fixed Focus (Initial Only)
Fast Stack
Exhaustive Stack
Predictive
Predictive Stack
Fixed Focus (Initial Only)
Fast Stack
Exhaustive Stack
Predictive
Predictive Stack
Fixed Focus (Initial Only)
Fast Stack
Exhaustive Stack
Predictive
Predictive Stack
Scan Time6
SD: 1:45
HD: 2:30
SD: 5:15
HD: 7:45
SD: 20:45
HD: 33:30
Included SoftwareuScope Navigator v4uScope Navigator v4uScope Navigator v4
Optional SoftwareuScope EDF4 v1uScope EDF4 v1uScope EDF4 v1
Scan Field Image Format
Compressed (JPG Q90)
Uncompressed (PNG)
Compressed (JPG Q90)
Uncompressed (PNG)
Compressed (JPG Q90)
Uncompressed (PNG)
Whole Slide Image Format
Deep Zoom Pyramid
Tiled TIFF (SVS)
Easy Zoom (SZI)
Deep Zoom Pyramid
Tiled TIFF (SVS)
Easy Zoom (SZI)
Deep Zoom Pyramid
Tiled TIFF (SVS)
Easy Zoom (SZI)
Net Weight
6.2 lbs
2.9 kg
6.2 lbs
2.9 kg
6.2 lbs
2.9 kg
Dimensions4.12" × 6.67" × 8.84"
104mm × 169mm × 224mm
4.12" × 6.67" × 8.84"
104mm × 169mm × 224mm
4.12" × 6.67" × 8.84"
104mm × 169mm × 224mm
Image  uScopeHXII: Tissue Sample (20x) uScopeHXII: Tissue Sample (40x)
Brochure
 uScopeHXII-10
Product Information
uScopeHXII-20
Product Information
uScopeHXII-40
Product Information

1 The uScopeHXII is a single-objective whole slide scanner. Each uScopeHXII model includes the specified objective (10x, 20x, or 40x). Neither digital pixel doubling nor interpolation are used to achieve the specified magnification.

2 The camera can operate in one of two modes: HD where each pixel on the image sensor maps to one pixel on the captured image; or SD where a 2×2 array of pixels is used to generate one pixel on the captured image (this is often referred to as binning). HD mode provides higher resolution images (comparable to the next higher magnification objective) where SD mode provides better contrast and less camera noise.

3 Z-Stacking simply means that the scanner captures several images at different focus levels for each field of view. The uScope Navigator software composites these into a whole slide image with a focus adjustment that allows you to view each layer of the Z-stack using a natural control similar to the focus knob of a traditional microscope. Note: Z-Stacking requires significantly more time to scan a slide as many times more images are captured and saved to disk for each scan field.

4 EDF (extended depth-of-field) is an image processing technique that takes the best focus parts of each image from a Z-Stack and creates a new image where everything is in focus. This technique can be very beneficial for extremely thick sections where the natural depth-of-field of the objective is too shallow to show each discrete element in focus. Note: Optional software is required to create EDF whole slide images. Compositing EDF scan fields is a very processor-intensive operation that is best suited to multi-core CPUs.

5 The uScopeHXII offers a number of different focus methods to accommodate a wide variety of specimen types and preparation. Specimens that are extremely thin can be scanned very well using predictive focus, fast stack, or even fixed focus. Thicker or inconsistent sections are best scanned with the exhaustive focus or predictive stack focus methods.

6 Scan speed is measured by scanning a 15mm×15mm area using the Predictive focus method. Fixed focus scans are slightly faster. Focus stack methods are slower (but may yield better focused images).

Contact Microscopes International or speak with your local distributor.